•Cubic leveraged existing mature NDIR technology and A2L refrigerant gas sensor product platform to fulfill customize refrigerant gas sensing solution
•Multiple A2L & A3L gases available, include R32,R454A,R454B,R454C,R455A, & R290
•Dual beam NDIR design secure the sensor with excellent accuracy and long term stability,also fulfill free of calibration during life time
•AM4205 series designed and tested to meet UL 60335-2-40 standard with 5V input, UART & Analog Output
•Based on mature AM4205 series, the AM4203 series has incorporated outputs to extend with RS485, Relay Outputs, 12V/24VDC power supply and Modbus communication protocol. It provides more efficiently integration with customer controlling systems
Key Features | NDIR | Metal-Oxide-Semiconductor | Thermal Conductivity | Comparison |
Selectivity | Excellent | Poor | Fair | NDIR with excellent selectivity MOS easily poison and impact by interference gas |
Accuracy | Excellent | Fair | Fair | NDIR Matrix calibration to ensure accuracy MOS and TC sensitive to temperature and humidity change |
Response | Excellent | Fair | Poor | NDIR Fast response MOS slow recovery rate, need long time preheat |
Temperature and Humidity Impact | No Impact | Accuracy Easily Influenced | Accuracy Easily Influenced | TC easily impacted by temperature and humidity |
Life time | Excellent | Poor | Fair | NDIR long-term stability, no false alarm MOS short life time, possible for false alarm TC has relatively longer life time than MOS, but still shorter with NDIR |
UL60335 compliance | Fully Compliant | Not Fully Compliant | Not Fully Compliant | Cubic NDIR sensor could fully comply with UL60335 & EN60079 Neither MOS or TC is comply with UL60335-2-40 Annex LL |